Mini PACSGTB-MINI-PACSUser Manualwww.gefentoolbox.com

Strona 2

6How to Connect the Mini PACS1. Connect the included RS-232 cable between the Mini PACS and the RS-232 device.2. Connect up to three (3) single or dua

Strona 3 - ASKING FOR ASSISTANC

7CONFIGURING THE IP ADDRESSSetting the IP AddressThe Mini PACS is designed to control devices over a network using a built-in Web server or via Telnet

Strona 4

8If you computer has an IP address of 192.168.1.(x), and192.168.1.72 is an available address, you can access the Mini PACS by entering 192.168.1.72in

Strona 5 - INTRODUCTIO

93. Click on the Properties button to display the Local Area Connection Properties dialog.4. Click on Internet Protocol Version 4 (TCP/IPv4).5. Click

Strona 6 - OPERATION NOTE

10CONFIGURING THE IP ADDRESS6. Change the IP settings to the following:*If the IP address192.168.1.80 is already in use on your network, chooseanother

Strona 7

11CONFIGURING THE IP ADDRESS7. Click the OK button, then close all Control Panel windows.8. Refresh your Web browser and go tohttp://192.168.1.72 to o

Strona 8 - ANEL LAYOU

12WEB INTERFACEThe Built-in Web ServerThe Mini PACS includes a built-in Web server which provides an intuitive Web interface. If TCP/IP is not confi g

Strona 9 - ANEL DESCRIPTION

13WEB INTERFACERS-232 MenuThe RS-232 Menu allows you to change the RS-232 port settings on the MiniPACS.DescriptionProvide a name to the deviceconnect

Strona 10 - CONNECTING THE MINI PAC

14WEB INTERFACERS-232 SettingsSome RS-232 settings use a drop-down menu for selecting different options.For example, to select the Baud Rate, click th

Strona 11 - CONFIGURING THE IP ADDRES

15WEB INTERFACETCP / UDP Bridging SettingsUDP Protocol is used by some control systems, including Gefen’s GAVA system,for faster response. When using

Strona 13

16WEB INTERFACETCP / UDP Bridging SettingsUDP Local PortRange: 1024 - 65535UDP Remote IPUDP Remote PortRange: 1024 - 65535Factory DefaultSets the sele

Strona 14

17WEB INTERFACEIR Emitters MenuThe Mini PACS has three (3) IR Emitter (IR back-channel) ports. The Mini PACScan use any one of these IR Emitter ports

Strona 15

18WEB INTERFACEAdvanced ViewClick this link to toggle betweenBasic View and AdvancedView.Command NameUsed to enter / edit the name of eachIR command.

Strona 16 - WEB INTERFA

19WEB INTERFACEAdvanced ViewClick the Advanced View linkto display additional optionsfor learning or deleting IR commands.LearnClick the Learn button

Strona 17

20WEB INTERFACENameThis is the Device Name of the currently-displayed Device. It is case-sensitive. You cannot edit the name. If youchange it, then

Strona 18

21WEB INTERFACEDevice IDThe Mini PACS assigns an internal number to each Device in memory. You can use this number to keep track of the number of Devi

Strona 19

22WEB INTERFACEAdding a new IR DeviceThe Mini PACS can hold up to 20 IR devices in memory. Each device may haveup to 64 Commands. If you are buildin

Strona 20

23WEB INTERFACE10. Find the IR remote for the new device. Make sure the batteries are fresh! Hold the remote so it is pointing at the IR window on th

Strona 21

24WEB INTERFACE14. If the commands match, the Mini PACS will return to the main screen, and the new command will now be green.15.If a code is learned

Strona 22

25WEB INTERFACE<?xml version=”1.0” encoding=”UTF-8”?> <ir_emitter> <dn>Bedroom_DVD</dn><class>Disc</class> &

Strona 23

ASKING FOR ASSISTANCETechnical Support:Telephone (818) 772-9100 (800) 545-6900Fax (818) 772-9120Technical Support Hours:8:00 AM to 5:00 PM Monda

Strona 24

26WEB INTERFACEAdding a new IR device from a TemplateTemplates are useful when you want to ensure that similar commands for different product models h

Strona 25

27WEB INTERFACE6. Since this is a template fi le, the Command Names will be yellow, rather thangreen. This means that only the names, and not the IR d

Strona 26

28WEB INTERFACE12. If the commands match, the Mini PACS will prompt you for the nextCommand in the list.13.If you are prompted for a command that does

Strona 27

2918. You can delete any commands that are not available for that specifi c remote by clicking the “Delete” button for those commands. Deleted buttons

Strona 28

30WEB INTERFACERelays MenuThe Mini PACS provides twoNormally-Open (NO) relays which can be used for controlling lighting systems, curtains, motorized

Strona 29

31WEB INTERFACEDevice NameEnter the name of the deviceassociated with this trigger.Default StateSets the default stateof the trigger. Options:Open, Cl

Strona 30

32WEB INTERFACETesting RelaysPress the “Set Closed” or “Set Open” buttons to manually change the state of arelay. If the “Type” is set to “Pulse”, th

Strona 31

33WEB INTERFACEConfi guration MenuThe Confi guration Menu allows management of TCP/IP confi guration, login credentials, fi rmware upgrades, and system re

Strona 32

34WEB INTERFACESubnetSets the subnet mask.The default settings is255.255.255.0GatewaySets the IP address of your router (IP gateway). Maximum value f

Strona 33

35WEB INTERFACETelnet Login SettingsPasswordSets the password. Maximum password length is 20 characters. The password is case-sensitive.Save Changes

Strona 34

CONTENTS1 Introduction2 Operation Notes3 Features4 Panel Layout5 Panel Descriptions6 Connecting the Mini PACS6 Wiring Diagram7 Confi guring the IP Ad

Strona 35

36WEB INTERFACEFirmware UpdateUpdateClick the Update buttonafter the fi rmware fi le has been selected using the Browse... button.Get FirmwareChecks the

Strona 36

37WEB INTERFACESystem ResetYes To AllCheck this box to perform aSystem-Wide Reset during areset procedure.Set Triggers To defaultPlace a check mark in

Strona 37

38WEB INTERFACEDelete IR CommandsPlace a check mark in the box to delete all learned IR commands during a reset.Delete IR Devices & CommandsPlace

Strona 38

39WEB INTERFACESystem SettingsThe System Settings section allows you to upload or restore a fi le containingall of the IP settings, RS-232 settings, tr

Strona 39

40WEB INTERFACEIt is important to understand that this XML fi le does not actually exist in the Mini PACS. Rather, it is created “on-the-fl y” by the W

Strona 40

41IP (TELNET) CONTROL SETUPThe Mini PACS may be manually operated using the Web server Graphical User Interface (GUI), or by an automation system (suc

Strona 41

42IP (TELNET) CONTROL SETUP3. Click “Save Settings”.4.Open HyperTerminal or another Terminal Emulation program on your computer.5. Open a new session

Strona 42

43RS-232 / TELNET COMMANDSIP Confi gurationCommandDescription#change_relay_stateChanges the current relay state#display_telnet_welcomeSet Telnet welcom

Strona 43

44#change_relay_state CommandThe #change_relay_state command changes the state of a relay. Specify the relay number and then the initial state (open

Strona 44

45#load_relay_params CommandThe #load_relay_params command loads relay settings from memory.Syntaxy:#load_relay_paramsParameters:None#save_relay_param

Strona 45

1Congratulations on your purchase of the Mini Professional Automation Control System. Your complete satisfaction is very important to us.GefenGefen d

Strona 46

46RS-232 / TELNET COMMANDS#set_pass CommandThe #set_pass command sets Telnet password. The maximum length of theparam1 is 20 characters. The passwor

Strona 47 - RS-232 / TELNET COMMAND

47RS-232 / TELNET COMMANDS#set_serial_mode CommandThe #set_serial_mode command sets the serial port mode.Syntaxy:#set_serial_mode param1Parameters:par

Strona 48

48RS-232 / TELNET COMMANDS#set_serial_params CommandThe #set_serial_params command sets the serial port parameters.Syntaxy:#set_serial_params param1 p

Strona 49

49RS-232 / TELNET COMMANDS#set_telnet_port CommandThe #set_telnet_port command sets the Telnet listening port. The default portvalue is 23.Syntaxy:#s

Strona 50

50RS-232 / TELNET COMMANDS#sgateway CommandThe #sgateway sets the IP gateway (router) address. Dot-decimal notation must be used when specifying the

Strona 51

51RS-232 / TELNET COMMANDS#show_relay_params CommandThe #show_relay_params command displays the current relay parameters. param1 specifi es the relay c

Strona 52

52RS-232 / TELNET COMMANDS#show_serial_params CommandThe #show_serial_params command displays the serial port parameters.Syntaxy:#show_serial_paramsPa

Strona 53

53RS-232 / TELNET COMMANDS#sipadd CommandThe #sipadd command sets the IP address for the Mini PACS. Dot-decimal notation must be used when specifying

Strona 54

54RS-232 / TELNET COMMANDS#system_wide_reset CommandThe #system_wide_reset command performs a system-wide reset. Each param-eter specifi es the hardwa

Strona 55

55RS-232 / TELNET COMMANDS#use_telnet_pass CommandThe #use_telnet_pass command requires or disables login credentials.Syntaxy:#use_telnet_pass param1P

Strona 56

2READ THESE NOTES BEFORE INSTALLING OR OPERATING THE PROFESSIONAL AUTOMATION CONTROL SYSTEM• The Mini PACS is shipped with a static IP address of 192

Strona 57

56RS-232 / TELNET COMMANDSBridging SettingsRS-232 Feedback and DelimitersOne advantage of RS-232 serial control over IR control is that RS-232 offers

Strona 58

57RS-232 / TELNET COMMANDSCommandDescription#set_addelSets add delimiter mode#set_end_delSets end-delimiter mode and value#set_send_byte_cntSets the e

Strona 59

58RS-232 / TELNET COMMANDS#set_end_del CommandThe #set_end_del command sets the end-delimiter mode and value.Syntaxy:#set_end_del param1 param2Paramet

Strona 60

59#set_send_time_out CommandThe #set_send_time_out command sets the timeout value for sending data collected from a device to the control system in Br

Strona 61

60RS-232 / TELNET COMMANDS#set_start_del CommandThe #set_start_del command sets the start-delimiter mode and value.Syntaxy:#set_start_del param1 param

Strona 62

61#set_tcp_br_port CommandThe #set_tcp_br_port command sets the TCP Bridge server listening port.Syntaxy:#set_tcp_br_port param1Parameters:param1 Po

Strona 63

62RS-232 / TELNET COMMANDS#set_udp_br_port CommandThe #set_udp_br_port command sets the UDP server listening port.Syntaxy:#set_udp_br_port param1Param

Strona 64

63RS-232 / TELNET COMMANDSIR Device SetupCommandDescription#add_classSpecifi es the Class of the device#add_device Adds a new device#add_manufacturerSp

Strona 65

64RS-232 / TELNET COMMANDS#add_device Command (required)The #add_device command adds a new device. The ADD_DEVICE commandmust be excuted before learn

Strona 66

65RS-232 / TELNET COMMANDS#add_mod_num Command (optional)The #add_mod_num command adds or updates the “Model No.” tag for the specifi ed device. The “

Strona 67

3Features•Control A/V devices using IR, RS-232 control, and relays over a Web-basedIP control system• Confi gurable Ethernet input supports Telnet, Web

Strona 68

66RS-232 / TELNET COMMANDS#delete_ir_cmd CommandThe #delete_ir_cmd command deletes the IR command from the specifi eddevice.Syntaxy:#delete_ir_cmd para

Strona 69

67RS-232 / TELNET COMMANDS#learn_ir_cmd CommandThe #learn_ir_cmd command initializes the learning of a new IR command.Syntaxy:#learn_ir_cmd param1 par

Strona 70

68RS-232 / TELNET COMMANDS#play_ir_cmd CommandThe #play_ir_cmd command plays an IR command stored in memory.Syntaxy:#play_ir_cmd param1 param2 param3P

Strona 71

69RS-232 / TELNET COMMANDS#show_device_tags CommandThe #show_device_tags command shows the existing tags (Class,Manufacturer and Model Number) for a s

Strona 72

70#show_devices CommandThe #show_devices command displays all devices in the IR list.Syntaxy:#show_devicesParameters:NoneExample:p#show_devicesDevices

Strona 73

71RS-232 / TELNET COMMANDS#show_ir_cmds CommandThe #show_ir_cmds command displays all IR commands for a stored device.Syntaxy:#show_ir_cmds param1Para

Strona 74

72RS-232 / TELNET COMMANDS#show_ir_data CommandThe #show_ir_data command displays raw data from the memory.Syntaxy:#show_ir_cmd param1 param2Parameter

Strona 75

73RS-232 / TELNET COMMANDSFor remotes with toggle bits there will be additional data:Command: 9 for Device: tvCarrier frequency = 40.000 KhzCarrier va

Strona 76

74General QueryCommandDescription#help Displays a complete list of commands#ipconfi g Displays all TCP/IP settings#show_ver_dataDisplays the Mini PACS

Strona 77

75RS-232 / TELNET COMMANDS#ipconfi g CommandThe #ipconfi g displays all TCP/IP settings.Syntaxy:#ipconfi gParameters:NoneExample:p#ipconfi g-------------

Strona 78

4PANEL LAYOUTTopFrontBack78431265

Strona 79

76RS-232 / TELNET COMMANDS#show_ver_data CommandThe #show_ver_data command displays the Mini PACS version information.Syntaxy:#show_ver_dataParameters

Strona 80

77 Controlling the Mini PACS via RS-232The Mini PACS is generally intended to be controlled via IP, in order to control RS-232, IR, and trigger-operat

Strona 81

78APPENDIXLearning IR Commands via TelnetThe Mini PACS has eight (3) IR Emitter outputs. Each of these IR Emitters can be connected to device. The M

Strona 82 - APPENDIX

796. If the Mini PACS verifi es that the data is the same, then it is saved:Data compare ok, checking for available space in FLASHNew command saved in

Strona 83

80Relays... (2) NO relay contacts with +12V DC and GroundRelay Connections...

Strona 84 - SPECIFICATION

81WARRANTYGefen warrants the equipment it manufactures to be free from defects in material and workmanship.If equipment fails because of such defects

Strona 87

Rev A21.1120600 Nordhoff St., Chatsworth CA 913111-800-545-6900 818-772-9100 fax: 818-772-9120www.gefentoolbox.com [email protected]

Strona 88 - E listed power supplies

51PowerThis LED will indicate the current power state. The LED is green when the unit is powered ON.2 IR SensorThe IR receiver is provided for the Mi