Gefen GEF-3GSDI-16416 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Skrzynki przełączników szeregowych Gefen GEF-3GSDI-16416. Gefen GEF-3GSDI-16416 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - 16x16 3GSDI Matrix

1080P16x16 3GSDI MatrixGEF-3GSDI-16416User Manualwww.gefenpro.com

Strona 2 - ASKING FOR ASSISTANCE

7PANEL DESCRIPTIONSBack Panel1 Reference In ConnectorConnect an external reference to this connector. Bi-level (black burst) and tri-level sync are

Strona 3 - CONTENTS

8How to Connect the 16x16 3GSDI Matrix1. Connect up to 16 3G-SDI source devices to the 3G-SDI inputs on the rear panel of the 16x16 3GSDI Matrix usin

Strona 4 - INTRODUCTION

9The Standby ScreenThe front panel of the 16x16 3GSDI Matrix has a 16 character 2 line LCD display. This display will shows the current routing status

Strona 5 - OPERATION NOTES

10CONNECTING AND OPERATING THE 16X16 3GSDI MATRIXSwitching between RS-232 and RS-485 ProtocolsPress the ► button to display the serial interface selec

Strona 6 - FEATURES

11In the example below, TERMINATION Off has been selected. The LCD will now show that the RS-485 protocol has been selected, along with the terminati

Strona 7 - PANEL LAYOUT

12Displaying the Routing StatusFrom the main screen, press the Select button. When the arrow cursor is next to OUTPUT, pressing the ◄ or ► buttons on

Strona 8

13IR REMOTE DESCRIPTIONRMT-16416IRRemote Control Unit1 Activity IndicatorThis LED will be activated momentarily each time a button is pressed.2 Displ

Strona 9

14Installing the RMT-16416IR Battery1. Remove the battery cover on the back of the IR Remote Control unit.2. Insert the included battery into the op

Strona 10 - PANEL DESCRIPTIONS

15IR REMOTE CONFIGURATIONHow to Resolve IR Code Confl ictsIn the event that IR commands from other remote controls interfere with the supplied IR Remot

Strona 11 - GEF-3GSDI-16416

16What features are available via the RS-232 serial communications port?The 16x16 3GSDI Matrix can accept commands through the RS-232 serial communica

Strona 12

ASKING FOR ASSISTANCERev A3Technical Support:Telephone (818) 772-9100 (800) 545-6900Fax (818) 772-9120Technical Support Hours:8:00 AM - 5:00 PM

Strona 13

17RS-232 SERIAL CONTROLRS-232 FeaturesRS-232 remote functions are used to control this product’s features. Features include input / output routing and

Strona 14

18RS-232 SERIAL CONTROL#PRREFTABLE FunctionThe #PRREFTABLE function displays the Reference In data table (timings) which are recognized by the 16x16 3

Strona 15

19RS-232 SERIAL CONTROL#SNETMASK FunctionThe #SNETMASK function specifi es a new net mask.Syntax:#SNETMASK param1 param2 param3 param4Parameters:param1

Strona 16 - IR REMOTE DESCRIPTION

20RS-232 SERIAL CONTROL#SPORT FunctionSpecifi es a new port for a Web server.Syntax:#SPORT param1Parameters:param1 Port [0 - 255]Notes:A reboot is

Strona 17 - IR REMOTE INSTALLATION

21RS-232 SERIAL CONTROLGeneral FunctionsFunction Description#ACTIVEBOLO Enables the boot loader#FADEFAULT Sets IP Confi gurations to default settings#R

Strona 18 - IR REMOTE CONFIGURATION

22RS-232 SERIAL CONTROL#RMTIRADD FunctionThe #RMTIRADD function set the remote IR channel.Syntax:#RMTIRADD param1Parameters:param1 IR channel

Strona 19 - RS-232 SERIAL INTERFACE

23CommandsCommand DescriptionM Returns the current routing status of matrixR Routing commandS Routes a single input to all outputsM CommandThe M comma

Strona 20 - RS-232 SERIAL CONTROL

24RS-232 SERIAL COMMANDSS CommandThe S command routes a single input to all 16 3GSDI outputs.Syntax:s param1Parameters:param1 Input [1 - 16]Note

Strona 21

25IP CONTROLThe GefenPRO 16x16 3GSDI Matrix supports IP-based control using an integrated Web interface. To access this feature, an IP address, subnet

Strona 22

26IP CONTROLMaskingThe Masking page is used to hide an output from displaying any video. From this page, all outputs can be set to “Active” or “Mask”.

Strona 23

CONTENTS1 Introduction2 Operation Notes3 Features4 Panel Layout4 Front Panel5 Front Panel Descriptions6 Panel Layout6 Back Panel7 Back Panel

Strona 24

27IP CONTROLIP Confi gurationThe IP Confi guration page is used to set the IP settings that will be used to access the Web interface. The following item

Strona 25

28IP CONTROLBackup / RestoreThe Backup/Restore page is used to backup and restore complete setup confi gurations.Note: This feature will be implemente

Strona 26

29FIRMWARE UPDATEFirmware Update ProcedureTo Begin the update procedure the unit’s Boot Loader must be activated. To activate the Boot Loader please f

Strona 27 - RS-232 SERIAL COMMANDS

30FIRMWARE UPDATEFollow the on-screen instructions to complete the fi rmware update process:1. Press [1] on the computer keyboard to begin downloading

Strona 28 - IP CONTROL

31WARNING MESSAGESSystem FailureIn the case of a critical malfunction, the following warning message will be displayed on the Main Display:If the 16x1

Strona 29

32RACK MOUNT SAFETY INFORMATIONa. Maximum recommended ambient temperature: 45 ˚Cb. Increase the air fl ow to maintain the temperature inside the rack

Strona 30

33Input / Output • SDI (SMPTE 259MI up to 360 Mbps)• HD-SDI (SMPTE 292M up to 1.485 Gbps)• 3G-SDI (SMPTE 424M/425M up to 3.0 Gbps)Supported Formats

Strona 31

34WARRANTYGefen warrants the equipment it manufactures to be free from defects in material and workmanship.If equipment fails because of such defects

Strona 32 - FIRMWARE UPDATE

35LICENSINGlwIP is licenced under the BSD licence:Copyright (c) 2001-2004 Swedish Institute of Computer Science.All rights reserved.Redistribution and

Strona 33

Rev A3Pb20600 Nordhoff St., Chatsworth CA 913111-800-545-6900 818-772-9100 fax: 818-772-9120www.gefenpro.com [email protected]

Strona 34 - WARNING MESSAGES

1Congratulations on your purchase of the 16x16 3GSDI Matrix. Your complete satisfaction is very important to us.GefenGefen delivers innovative, progre

Strona 35 - RACK MOUNT SAFETY INFORMATION

2READ THESE NOTES BEFORE INSTALLING OROPERATING THE 16X16 3GSDI MATRIX• There is no internal scaling in the 16x16 3GSDI Matrix. All of the attached m

Strona 36 - SPECIFICATIONS

3Features• Increases productivity• Supports resolutions up to 1080p, 1920x1200, and 2K.• Front panel control buttons for local switching.• Status L

Strona 37 - PRODUCT REGISTRATION

4Front PanelPANEL LAYOUT4 5 6213

Strona 38 - LICENSING

5PANEL DESCRIPTIONSFront Panel1 LCD DisplayDisplays the current routing status of the Matrix and is also used to manage source routing.2 Power SwitchT

Strona 39

6PANEL LAYOUTBack Panel4 58961327

Komentarze do niniejszej Instrukcji

Brak uwag