Gefen EXT-IP-2-RS2322 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Dodatkowe wyposażenie muzyczne Gefen EXT-IP-2-RS2322. Gefen EXT-IP-2-RS2322 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 84
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Audio
Embedder
3GSDI
EXT-IP-2-RS2322
User Manual
IP to RS-232
Converter
*Preferred
Release A1
Przeglądanie stron 0
1 2 3 4 5 6 ... 83 84

Podsumowanie treści

Strona 1 - IP to RS-232

Audio Embedder 3GSDI EXT-IP-2-RS2322User ManualIP to RS-232 Converter*PreferredRelease A1

Strona 3 - Warranty Information

IP to RS-232 Converter1 Getting StartedIntroduction...

Strona 4

page | 2IntroductionRS-232 1 PowerIP ResetEXT-IP-2-RS2322Gefen5V DC IP control RS-232 2IP to 2xRS-232ConverterRS-232 1 PowerIP ResetEXT-IP-2-RS2322Gef

Strona 5 - Operating Notes

page | 3IntroductionID Name Description1 IP Reset Resets the unit to its default IP settings.2 RS-232 1 Connect an RS-232 cable from this port to an R

Strona 6 - Features and Packing List

page | 4InstallationGetting StartedConnection Instructions1. Connect an Ethernet cable between the IP-based control device and the IP control port on

Strona 9

page | 7IP to RS-232 Converter2 Advanced OperationRS-232 and IP Conguration ...

Strona 10

page | 8RS-232 and IP CongurationAdvanced OperationAdvanced OperationConfiguration using the Gefen Discovery ToolWhen using the IP to 2 x RS-232 Conv

Strona 11

page | 9Advanced OperationConfiguration using RS-232To congure the IP settings of the IP to 2 x RS-232 Converter using RS-232 commands, use the follo

Strona 12 - Introduction

ii1. Read these instructions.2. Keep these instructions.3. Heed all warnings.4. Follow all instructions.5. Do not use this product near water.6.

Strona 13 - Getting Started

page | 10RS-232 and IP CongurationAdvanced OperationAdvanced Operation5. Set the gateway (router) IP address using the #set_gateway command.6. Set

Strona 14 - Installation

page | 11Advanced OperationCommand Description#helpDisplays a list of all available commands#set_add_delimEnables or disables option to add delimiter

Strona 15

page | 12Advanced OperationAdvanced OperationCommandsCommand Description#show_serial_paramsDisplays the settings of the specied RS-232 port#show_teln

Strona 16

page | 13Advanced OperationCommands#helpDisplays help on a specic command. If no command is specied (param1), then a list of all available commands

Strona 17

page | 14CommandsAdvanced OperationAdvanced Operation#help #show_ipcong#set_ipadd#set_netmask#set_gateway#set_http_port#set_tcp_term_port#set_udp_por

Strona 18 - RS-232 and IP Conguration

page | 15CommandsAdvanced Operation#set_add_delimEnables or disables the option to include a delimiter as part of the data sent to the control system.

Strona 19 - Configuration using RS-232

page | 16CommandsAdvanced OperationAdvanced Operation#set_device_descrSets the device description. The device description cannot exceed 30 characters

Strona 20 - Information

page | 17CommandsAdvanced Operation#set_end_delSets the end-delimiter mode and value for the specied serial port. The End Delimiter value must be spe

Strona 21 - Commands

page | 18Commands#set_gatewaySets the gateway address. The gateway must be typed using dot-decimal notation. The matrix must be rebooted after exec

Strona 22 - Advanced Operation

page | 19Commands#set_http_portSpecies the Web server listening port. The unit must be rebooted after executing this command. The default port sett

Strona 23 - Parameters

iiiGefen warrants the equipment it manufactures to be free from defects in material and workmanship.If equipment fails because of such defects and Gef

Strona 24

page | 20Commands#set_ipaddSpecies the IP address of the IP to 2 x RS-232 Converter. The IP address must be specied using dot-decimal notation. Th

Strona 25 - #set_add_delim

page | 21Commands#set_netmaskSets the subnet mask. The subnet mask must be entered using dot-decimal notation. The unit must be rebooted after execut

Strona 26 - #set_device_descr

page | 22Commands#set_send_byte_cntSets the send-byte count value for bridging mode.Syntax#set_send_byte_cnt param1Parametersparam1 Serial port

Strona 27 - #set_end_del

page | 23Commands#set_send_time_outSets the time-out value for sending data collected from a device to the control system in Bridging Mode when a Star

Strona 28 - #set_gateway

page | 24Commands#set_serial_descrAssigns a descriptor to the specied serial port. The serial port description cannot exceed 20 characters in length.

Strona 29 - #set_http_port

page | 25Commands#set_serial_modeSets the mode of the specied serial port. The default mode for all serial ports (1 - 2) is TCP Bridge mode.Syntax#s

Strona 30 - #set_ipadd

page | 26CommandsAdvanced OperationAdvanced Operation#set_serial_paramsAssigns the settings to the specied serial port.Syntax#set_serial_params param

Strona 31 - #set_netmask

page | 27CommandsAdvanced OperationExample#set_serial_params 1 8 1 N 19200 1000 Serial port 1 parameters: Word length = 8 bits Stop bits = 1 bit Pa

Strona 32 - #set_send_byte_cnt

page | 28CommandsAdvanced OperationAdvanced Operation#set_start_delSets the Start Delimiter mode and value for the specied serial port. The Start Del

Strona 33 - #set_send_time_out

page | 29CommandsAdvanced Operation#set_tcp_br_portSets the TCP bridge listening port for the specied serial port. The default port settings for RS-2

Strona 34 - #set_serial_descr

ivTechnical Support(818) 772-9100 (800) 545-6900 8:00 AM to 5:00 PM Monday - Friday, Pacic TimeFax(818) [email protected]://www.

Strona 35 - #set_serial_mode

page | 30CommandsAdvanced OperationAdvanced Operation#set_tcp_term_portSets the TCP terminal listening port. The default port settings is 23.Syntax#s

Strona 36 - #set_serial_params

page | 31CommandsAdvanced Operation#set_telnet_passSets the TCP Terminal password. The password cannot exceed 20 characters in length. param3 is use

Strona 37 - Related Commands

page | 32CommandsAdvanced OperationAdvanced Operation#set_udp_br_portSets the UDP bridge listening port. The default UDP bridge port settings for RS-2

Strona 38 - #set_start_del

page | 33CommandsAdvanced Operation#set_udp_echo_brEnables or disables UDP bridge echo.Syntax#set_udp_echo_br param1 param2Parametersparam1 Serial

Strona 39 - #set_tcp_br_port

page | 34CommandsAdvanced OperationAdvanced Operation#set_udp_portSets the UDP server listening portSyntax#set_udp_port param1Parametersparam1 Ser

Strona 40 - #set_tcp_term_port

page | 35CommandsAdvanced Operation#set_udp_remote_brAssigns the UDP Bridge settings for the specied serial port. param2 must be entered in dot-deci

Strona 41 - #set_telnet_pass

page | 36CommandsAdvanced OperationAdvanced Operation#set_udp_ripSets the remote UDP IP address. The IP address must be entered using dot-decimal not

Strona 42 - #set_udp_br_port

page | 37CommandsAdvanced Operation#set_udp_rportSets the remote UDP listening port. The default port settings is 50008.Syntax#set_udp_rport param1Pa

Strona 43 - #set_udp_echo_br

page | 38CommandsAdvanced OperationAdvanced Operation#show_del_prmsDisplays the current delimiter parameters for the specied serial port.Syntax#show_

Strona 44 - #set_udp_port

page | 39CommandsAdvanced Operation#show_device_descrDisplays the device description.Syntax#show_device_descrParametersNoneExample#show_device_descr D

Strona 45 - #set_udp_remote_br

vvOperating Notes• When using the IP to 2 x RS-232 Converter for the rst time, it is recommended that the unit be congured using the Gefen Discover

Strona 46 - #set_udp_rip

page | 40CommandsAdvanced OperationAdvanced Operation#show_ipcongDisplays the current TCP/IP and UDP settings.Syntax#show_ipcongParametersNoneExampl

Strona 47 - #set_udp_rport

page | 41CommandsAdvanced Operation#show_meEnables or disables the ashing of the LED on the device. When enabled, the LED indicator will ash red and

Strona 48 - #show_del_prms

page | 42CommandsAdvanced OperationAdvanced Operation#show_serial_descrDisplays the description of the specied serial port.Syntax#show_serial_descr p

Strona 49 - #show_device_descr

page | 43CommandsAdvanced Operation#show_serial_modeDisplays the mode of the specied serial port.Syntax#show_serial_mode param1Parametersparam1 P

Strona 50 - #show_ipcong

page | 44CommandsAdvanced OperationAdvanced Operation#show_serial_paramsDisplays the current settings of the specied serial port.Syntax#show_serial_p

Strona 51 - #show_me

page | 45CommandsAdvanced Operation#show_telnet_passDisplays the current TCP terminal password.Syntax#show_telnet_passParametersNoneExample#show_telne

Strona 52 - #show_serial_descr

page | 46CommandsAdvanced OperationAdvanced Operation#show_ver_dataDisplays the current software and hardware version.Syntax#show_ver_dataParametersNo

Strona 53 - #show_serial_mode

page | 47CommandsAdvanced Operation#system_wide_resetRestarts the IP to 2 x RS-232 Converter according to the supplied parameter.Syntax#system_wide_re

Strona 54 - #show_serial_params

page | 48CommandsAdvanced OperationAdvanced Operation#use_discoveryEnables or disables discovery access mode. If this mode is disabled, then theIP to

Strona 55 - #show_telnet_pass

page | 49CommandsAdvanced Operation#use_tcp_accessEnables or disables TCP access mode. This mode must be enabled before using RS-232 command to congu

Strona 56 - #show_ver_data

viFeatures and Packing ListFeatures• Allows IP control of two RS-232-enabled devices• Supports Telnet and UDP protocols• Each of the RS-232 devices

Strona 57 - #system_wide_reset

page | 50CommandsAdvanced OperationAdvanced Operation#use_tcp_term_passEnables or disables the use of the password during terminal sessions.Syntax#use

Strona 58 - #use_discovery

page | 51CommandsAdvanced Operation#use_udp_accessEnables or disables UDP access.Syntax#use_udp_access param1Parametersparam1 Value [0 ... 1]Va

Strona 59 - #use_tcp_access

page | 52#use_udp_echoEnables or disables UDP echo.Syntax#use_udp_echo param1Parametersparam1 Value [0 ... 1]Value Description0Disable UDP echo

Strona 60 - #use_tcp_term_pass

page | 53Advanced OperationWeb InterfaceUsing the built-in Web InterfaceAccess the built-in Web interface by entering the IP address of the IP to 2 x

Strona 61 - #use_udp_access

page | 54Web InterfaceRS-232Select RS-232 Port Select the RS-232 port from the drop-down list.Options: 1, 2 Description Enter a description for the de

Strona 62 - #use_udp_echo

page | 55Web InterfaceBaud Rate Select the baud rate used by the RS-232 device from this drop-down list.Options: 110, 300, 600, 1200, 2400, 4800, 9600

Strona 63 - Web Interface

page | 56Web InterfaceLine Delay (ms) Enter the line delay in this eld.Range: 0 ... 10000 Force Send (ms) If no data is received from the controlle

Strona 64

page | 57Web InterfaceAdd Delimiters to data sent Include the delimiter characters in the data sent to the control system. Check the Add box to enabl

Strona 65

page | 58Web InterfaceEnd Delimiter Value This value can be up to three ASCII characters (3 bytes), in length. The value must be entered in hexadecim

Strona 66

page | 59Web InterfaceDestination IP Enter the destination (where the data will be sent) IP address in this eld.Range (per byte): 0 ... 255 Destinati

Strona 68

page | 60Web InterfaceNetwork tabMAC Address The MAC address of the IP to RS-232 Converter. The MAC address cannot be changed. Mode Select the netw

Strona 69

page | 61Web InterfaceGateway The gateway (router) IP address to with the IP to 2 x RS-232 Converter is connected.Range (per byte): 0 ... 255 HTTP P

Strona 70 - Network tab

page | 62Web InterfaceEnable TCP Access Enables or disables TCP access. Options: Enable (checked), Disable (unckecked) Require Password on Connect

Strona 71

page | 63Web InterfaceNew Password Type the new password in this eld. The password is automatically masked when entered. The password is case-sensi

Strona 72

page | 64Web InterfaceEnable UDP Access Enables or disables UDP access. Options: Enable (checked), Disable (unckecked) UDP Port Sets the UDP port.R

Strona 73

page | 65Web InterfaceDestination UDP IP Address Enter the remote UDP IP address in this eld.Range (per byte): 0 ... 255 Destination UDP Port Type th

Strona 74

page | 66Web InterfaceAdvanced OperationAdvanced OperationSystem tabDownload (Download Current Conguration) Saves the current conguration of the IP

Strona 75

page | 67Web InterfaceAdvanced OperationBrowse... (Firmware Update) Click this button to select the rmware le to be uploaded. Update Click this butt

Strona 77

IP to RS-232 Converter3 AppendixDefault Settings ... 7

Strona 78

viiiTable of Contents1 Getting StartedIntroduction...

Strona 79

page | 70Default SettingsAppendixAppendixThe following table lists the default setting of the IP to 2 x RS-232 Converter, as displayed under the built

Strona 80 - Default Settings

page | 71AppendixNetworkIP SettingsMAC Address • Device-dependent (cannot be changed)Mode • StaticIP Address • 192.168.1.72Subnet • 255.255.255.0G

Strona 81 - Appendix

page | 72AppendixConnectors, Indicators, and ControlsRS-232 • 2 x DB-9, maleIP control • 1 x RJ-45Power • 1 x 5V DC, lockingPower indicator • 1 x

Strona 83

20600 Nordhoff St., Chatsworth CA 913111-800-545-6900 818-772-9100 fax: 818-772-9120www.gefen.com [email protected] it. Switch it. S